Use this guide to resolve access issues, scan failures, and unexpected Secret Scanning results. It also explains how scan allowances, source paths, and container discovery affect your results.
The ASPM tab is not available
- Confirm with your administrator that your account includes Sembi ASPM and that your user has access.
- Sign out and sign in again.
- Verify that you are using the expected Kiuwan account or tenant.
If ASPM remains unavailable, contact your administrator or Kiuwan Support.
Secret Scanning is unavailable or blocked
Secret Scanning requires a compatible Kiuwan Local Analyzer (KLA) installation, account access, permission for the target application, and an available monthly scan allowance.
Use the message displayed to identify the next step:
| Message | Action |
| “Secret scanning is not currently available on this installation. Update your Kiuwan Local Analyzer configuration and try again.” | Update your KLA configuration as instructed. Confirm that your installation supports the ASPM scanner and can download the scanner component. |
| “Contact your account manager to enable secret scanning for your account.” | Contact your account manager to enable Secret Scanning for the account. |
| “Secret scanning is not enabled for your user on this application.” | Ask your administrator to verify your Secret Scanning permissions for the target application. |
| “Secret scanning is not enabled for this account or application. Contact your account manager to enable it.” | Confirm that Secret Scanning is enabled for both the account and your user on the target application. Contact your account manager for enablement. |
| “Your monthly scan limit has been reached. Contact your account manager to increase your limit.” | Contact your account manager to increase the limit, or wait until the monthly allowance renews. |
| “Your monthly scan limit for Secret Scanning has been reached. Contact your account manager to increase your limit.” | Contact your account manager to increase the limit, or wait until the monthly allowance renews. |
KLA automatically downloads the scanner component on its first run and when Kiuwan publishes a new version. Kiuwan manages the scanner version.
The analysis fails
- Open the execution log from the Progress column.
- Record the exact error message, analysis time, analyzer version, application, and input type.
- Check connectivity to the required services, proxy settings, certificates, and permissions to read the source.
- Check whether the error indicates an access restriction or an exhausted scan allowance.
Server and upload errors
| Error | Meaning and action |
| Server rejection message from Kiuwan | Kiuwan refused the analysis. Review the displayed reason and address the reported issue. |
Error returned from Kiuwan: <reason> with exit code 22 |
The ASPM service rejected the upload, for example because the scan allowance was exceeded. Use the reason in the message to identify the corrective action. |
If the error persists, collect the details listed under Contact Support.
The analysis succeeds, but results do not appear
- Confirm that you selected the correct application and scan in Sembi ASPM.
- Verify that the scan completed successfully, then refresh the view.
- Check your selected reporting period. The Dashboard excludes projects without a completed scan in the last 30 days.
- Open Triage Workbench and select the scan. If it completed without findings, the table displays “No findings in this scan.”
If you expected findings, review the scanning scope and skipped-path rules below.
Understand what gets scanned
Source files
The scanner examines flat text files and compiled Python code under the source folder specified with -s, subject to the default path exclusions described below.
Container images
KLA searches the source folder for container image references and scans each unique image it discovers.
| Source | How images are discovered | Exclusions |
Dockerfile, Dockerfile.*, and *.dockerfile
|
Images referenced in FROM instructions. |
The scratch image and references containing variables, such as $VERSION, are skipped. |
docker-compose.yml, docker-compose.yaml, compose.yml, compose.yaml, and docker-compose.*.yml
|
image: entries under services. |
References containing variables are skipped. |
The number of unique images found is reported as containers discovered. The Dashboard’s Containers Scanned metric adds these reported counts from the included scans.
If an expected image is missing, check that its reference appears in a supported file and does not contain a variable.
Expected secrets are not reported
The scanner skips certain paths to reduce noise from test data, documentation, and third-party code. Skipped files produce no findings and no warnings in the console, execution log, or results.
A scan can therefore report zero findings even when files in excluded paths contain secrets.
Paths skipped by default
Exclusion rules apply to paths relative to the source folder specified with -s, rather than absolute paths from the disk root.
| Rule | Skipped paths |
| Test paths | Paths that start with test, regardless of case, or contain /test, -test, _test, or .test. Examples include test/, tests/, testdata/, Testing/, testProject/, my_test.py, app.test.js, my-test.py, and test_app.py. |
| Example paths | Paths containing example, such as example/, src/examples/, and app_example.py. |
| Markdown files | Files ending in .md. |
| Nested vendor folders | Paths containing a nested vendor folder, such as src/vendor/. A vendor/ folder directly inside the scanned source folder is scanned. |
| Nested locale folders | Paths containing a nested locale or locales folder, such as src/locales/. A locale/ or locales/ folder directly inside the scanned source folder is scanned. |
Test and example rules match path text, not just complete folder names. For example, testProject/ matches the test rule. Paths such as myTest/, protest/, src/contest.py, and src/latest/ do not match that rule.
How the source folder affects exclusions
Changing the folder passed with -s changes the relative paths evaluated by the scanner. The same file can therefore be scanned from one starting folder and excluded from another.
Folder passed with -s
|
Relative paths evaluated | Effect |
parent/testProject |
app.py, .env
|
The test-path rule does not exclude these files. |
parent |
testProject/app.py, testProject/.env
|
The files are skipped because their paths start with test. |
The same principle applies to vendor and locale folders. For example, scanning parent/proj exposes the relative path vendor/file.py, which is scanned. Scanning parent exposes proj/vendor/file.py, which is skipped.
When investigating a missing finding, check both the source folder passed with -s and the file’s path relative to that folder.
Result counts do not match
Before comparing counts, check that the views use the same project, scan, reporting period, and severity scope.
| View or metric | What to check |
| Dashboard summary metrics | Use the most recent completed scan within the rolling last 30 days for each included project you can access. |
| Projects | Uses the selected project and scan period. Latest scan analysis uses only the most recent completed scan. |
| Triage Workbench | Shows findings for the selected project and successful scan. Pagination counts location groups, which can contain multiple findings. |
| Open Criticals | Includes both Critical and High findings. |
| Local Files Scanned | Counts distinct file paths with at least one finding, rather than every file examined. |
| Containers Scanned | Adds the unique-image discovery counts reported by the included scans. |
Also check chart-specific time selectors. On the Dashboard, changing the Findings per Category period affects only that chart.
Contact Support
If the issue persists, contact Kiuwan Support and provide:
- Kiuwan Local Analyzer version and operating system.
- Application name and analysis time, including the time zone.
- Analysis or correlation identifier, if available.
- Selected Sembi ASPM view, project, scan, and reporting period.
- Exact error message and relevant execution-log details.
- For missing findings, the source folder is passed with
-sthe affected relative path, with sensitive details masked.
Remove or mask source code, credentials, tokens, private paths, and personal data from screenshots, logs, and attachments before sharing them.